Donaldson Company
Preventative Maintenance Schedule for Mist Collectors
Pages
2
Time to read
4 mins
Publication
Language
English
Pages
2
Time to read
4 mins
Publication
Language
English
This guide outlines the preventative maintenance schedule for mist collectors, detailing the frequency and procedures for various maintenance tasks. Daily tasks include monitoring the exhaust from the fan to ensure filter integrity and checking the mist drainage system for proper operation. Weekly inspections involve recording the pressure drop across mist collector filters and HEPA/DOP afterfilters, with specific attention to fluctuations that may indicate filter issues. Monthly maintenance requires verifying the conditions of pneumatic lines to ensure accurate pressure drop readings. Every six months, checks are performed on the fan and motor for correct operation and airflow adjustments are made to match design recommendations. Additionally, filters must be installed correctly during changes to prevent mist leakage. The guide emphasizes the importance of consulting the Installation and Operation Manual for troubleshooting and maintenance recommendations. It also includes a notice regarding factors affecting product performance, underscoring the necessity for users to evaluate product suitability for their specific applications.